Cardiac Science™ PowerHeart™ Replacement Battery 9141-001 9200 9210 Brand New !

$ 89.23

Availability: 171 in stock
  • All returns accepted: Returns Accepted
  • Condition: New
  • Item must be returned within: 30 Days
  • Country/Region of Manufacture: United States
  • Model: CARDIAC SCIENCE
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Type: 12v 7500 mAh
  • Country of Manufacture: United States
  • MPN: 9141-001
  • Brand: Zeller Power
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    You are looking at the
    only
    New
    FDA approved battery
    listed on EBAY! The others are "re-celled" claiming it is a new battery or a China product with inferior parts and not approved by the FDA.
    Please look at these ads closely so you don't put an inferior product into a device that is intended to save lives.
    Non-Rechargeable, FDA approved, Replacement Battery for Cardiac Science

    FirstSave

    Survivalink

    and Powerheart

    AED (NOT the G3

    Model). Replaces battery part # 9141-001, and Model part #'s: 9200d-2 & 9210d-2
    Chemistry: Sealed Li-SO2 (Lithium Sulfur Dioxide)
    Ratings: 12V 7.5Ah
    Version: Non-Rechargeable
    Typical Capacity: 12 hrs. of "On" Time / Up to 300 Full Discharges
    Compatibility: Replacement for Firstsave

    Survivalink

    / AED Model # 9200d-2 / 9210d-2
    Shelf Life: A new lithium battery pack has a shelf life of five (5) years stored at proper temperatures. Shelf life is defined as the length of time a battery can be stored, prior to installation into AED, without degrading its performance.        Proper storage temperature is between 0°C to +50°C (32°F to +122°F).
    Recommended Replace Interval: Three (3) years, depending upon usage.
    Self Testing: With the lithium battery pack installed, the AED automatically tests it as part of the Daily Auto test. In addition, every 28 days a self-test is performed to check overload, electrodes, electronics, energy charge cycle and software.
    Useful Life and Expected Capacity: When optimally maintained, a new lithium battery pack has a capacity of 7.5 Amp hours, which is equivalent to 12 hours of ?ON? time. It is important to know that just turning the AED on uses up battery capacity. Also, each year, battery capacity decreases while the battery is in the AED due to the normal self-discharge rate. After 4 years of absolutely no patient use, approximately 35% of the useful life will remain (4.9 hours of ?ON? time)
    Proper Maintenance: Do not attempt to recharge. Do not use beyond the expiration date marked on the label. Do not expose to temperatures greater than 50 degrees Celsius (122 F). Do not allow electrical connection between the contacts, as it can blow the internal fuse and disable the battery permanently.
    Item #:
    ZP-9141
    Condition:
    Brand New
    Warranty:
    4 Years